Comm setup for the slc 5/02, Comm setup for the slc 5/02 -5 – Hardy WS100 Configuration Software User Manual
Page 20

Chapter 4 - Setup
4-5
FIG. 4-3 REMOTE SELECTED/ENTER FILE#, STARTING WORD
Step 6.
Enter the integer number used in the Lad-
der Logic for remote operation of the HI
1746-WS Weigh Module in the textfield
next to “File#”. In our example we entered
the number 7.
Step 7.
Enter the starting number us in the Ladder
Logic for remote operation of the HI 1746-
WS Weigh Module in the textfield next to
“starting word”.
Step 8.
Click on the Save button to save the set-
tings.
Comm Setup for
the SLC 5/02
Normally the HI WS100 talks to the HI 1746-WS via
the “M Files”. The SLC 5/02 does not support com-
munication commands for direct reading and writing
of M Files. The SLC 5/02 supports commands to read
and write “integer” type files.
Step 1.
Write the ladder logic provided (See Fig.
4-4) to copy the integer file to the HI
12746-WAS’s M files. The ladder logic