Checkline Series-5 User Manual
Page 31
![background image](/manuals/656224/31/background.png)
Series 5 Digital Force Gauges
User’s Guide
30
13.3 Capacity, Resolution & Load Cell Deflection
Model
Capacity Resolution
Load Cell
Deflection
lbF ozF
kgF gF N kN mN lbF ozF kgF gF N
kN mN
M5-012
0.12 2
50
0.5
500 0.00002 0.0005
0.01 0.0001
0.1
0.005
[0.13]
M5-025
0.25
4
100
1
1000
0.00005
0.001
0.02
0.0002
0.2
0.010
[0.25]
M5-05
0.5
8
250
2.5
2500
0.0001
0.002
0.05
0.0005
0.5
0.010
[0.25]
M5-2
2
32
1
1000
10
0.0005
0.01
0.0002
0.2
0.002
0.010
[0.25]
M5-5
5
80
2.5
2500
25
0.001
0.02
0.0005
0.5
0.005
0.010
[0.25]
M5-10
10
160
5
5000
50
0.002
0.05
0.001
1
0.01
0.010
[0.25]
M5-20
20
320
10
10000
100
0.005
0.1
0.002
2
0.02
0.010
[0.25]
M5-50
50
800
25
25000
250
0.01
0.2
0.005
5
0.05
0.010
[0.25]
M5-100
100
1600
50
50000
500
0.02
0.5
0.01
10
0.1
0.010
[0.25]
M5-200
200
3200
100
1000
1
0.05
1
0.02
0.2
0.0002
0.010
[0.25]
M5-500
500
8000
250
2500
2.5
0.1
2
0.05
0.5
0.0005
0.010
[0.25]
M5-1000 1000
500
5000 5
0.5
0.2
2 0.002
0.015
[0.38]