Control master dip switch – Aviom 6416m/RCI/MCS User Manual
Page 75
64
v
irtuAl
d
AtA
c
Ables
VIRTUAL DATA CABLE PORTS
AC POWER
FUSE: 250VAC-F4AL
IN
OUT
1 2 3 4
1
2
3
4
RS-232
RESERVED
CONTROL MASTER
1–8
9
10
IN
OUT
ON
RS-232
1.75 AMP
PIN 1 = GND
PIN 4 = 24VDC
BACKUP POWER
GPIO INPUT
UP = ISOLATED
DN = TTL
9–16 THRU (ALT. IN)
1–8 THRU (ALT. IN)
Mic/Line Inputs (Bal) Pin 2 Hot
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Mic Input Module
B
A
Here, the 6416m is set for a 57,600 baud RS-232 transfer with 8 data bits, no
parity, and stop bit set to 2. (Black indicates the switch handle.)
The following table lists the DIP switch settings for the available RS‑232 baud
rates.
Switch
Baud Rate
1
2
3
4
1200
off
off
off
off
2400
off
off
off
on
4800
off
off
on
off
7200
off
off
on
on
9600
off
on
off
off
14400
off
on
off
on
19200
off
on
on
off
28800
off
on
on
on
38400
on
off
off
off
57600
on
off
off
on
31250 (MIDI)
on
off
on
off
Control Master DIP Switch
In the RS‑232 DIP switch block on the 6416m, switch #10 is used to set the
module as the network’s Control Master. Only one module can be designated
as Control Master in a Pro64 network.
VIRTUAL DATA CABLE PORTS
AC POWER
FUSE: 250VAC-F4AL
IN
OUT
1 2 3 4
1
2
3
4
RS-232
RESERVED
CONTROL MASTER
1–8
9
10
IN
OUT
ON
RS-232
1.75 AMP
PIN 1 = GND
PIN 4 = 24VDC
BACKUP POWER
GPIO INPUT
UP = ISOLATED
DN = TTL
9–16 THRU (ALT. IN)
1–8 THRU (ALT. IN)
Mic/Line Inputs (Bal) Pin 2 Hot
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Mic Input Module
B
A
When switch #10 is in the up position, the 6416m becomes the network’s