beautypg.com

5 symptom, Possible cause, Solution – Conair SC-5 User Manual

Page 83: Lectrical, Roblems c

background image

UGE059/1003

SC-5 SURE CUT Servo Knife Cutter

T

ROUBLESHOOTING

6-5

Symptom

After pressing

Start Cutter, the
cutter head rotates
slowly but does not
stop.

Master safety

relay does not ener-
gize

While in

Encoder mode, no
count is displayed

Possible cause

The Blade home proximi-
ty switch failed or the
connection to it is loose.

Guard circuit is open.

Input from encoder
failed.

Encoder failed.

Solution

Check connections and replace
switch if needed.

Check to see if:

❒ The blade guard is closed.
❒ Loose connection to guard

circuit. Tighten connec-
tion.

❒ Guard switch is bad.

Replace switch.

Check encoder cable for conti-
nuity. Connect any loose wires.

Replace encoder.

E

LECTRICAL

P

ROBLEMS

C

ONTINUED