beautypg.com

Reventative, Aintenance, Chedule c – Conair SC-5 User Manual

Page 71

background image

Weekly

Cleaning the blade lubrication tray (if the cutter
has this

option).

See Cleaning the Blade Tray,

Section 5.

Lubricating shafts on optional slide rail system

See Cleaning the Blade Tray, Section 5.

Monthly

Checking hardware on the knife guard

Inspect the hardware on the knife guard (fasteners on
hinge and the clear blade guard window). Tighten as
needed.

Checking bushing holder proximity switches

Inspect the sets screws which retain the bushing holder
proximity switches for tightness. Adjust as needed. See
Adjusting the Proximity Switches, Section 5.

Checking the draw latch

Inspect the latch on knife guard windows for wear and

P

REVENTATIVE

M

AINTENANCE

S

CHEDULE

C

ONTINUED

UGE059/1003

SC-5 SURE CUT Servo Knife Cutter

M

AINTENANCE

5-5

Clean the clear blade guard window

Clean using glass cleaner or plain water. Other materi-
als may cause premature loss of clarity or crazing.

Semi-annual (every 6 months)

Inspecting electrical terminals

Check all electrical terminals for tightness; adjust as
needed. See Checking Electrical Connections, Section
5.

Checking torque on Trantorque coupling device

Check the tightness (torque) of the Trantorque coupling
device with a torque gauge. This device connects the
cutter head to the Micron reducer shaft. See Checking
Torque, Section 5.

Checking all electrical cables

Inspect all electrical cables for cuts and abrasions.
Replace as needed.

Inspecting control panel lights

Check to make sure no LEDs or lights are burned out
on the control panel. Replace as needed.

Draw Latch