Lectrical, Roblems, Symptom – Conair SC-5 User Manual

Page 82: Possible cause, Solution

background image

SC-5 SURE CUT Servo Knife Cutter

UGE059/1003

6-4

T

ROUBLESHOOTING

E

LECTRICAL

P

ROBLEMS

Look in this section when you have problems such as lights on
the control that are working improperly, buttons that do not
execute the function properly, and when information input is
not executed properly.

Symptom

The green start

button does not
illuminate when
pressed

Pressing the cut

enable soft key and
cutter does not
start cutting

Pressing the

Reset/Test button
does not produce a
cut when in an on-
demand mode.

Possible cause

The E-stop button is
pushed in.

A safety switch has failed.

There is a loose connec-
tion.

The relay is bad.

The guard circuit failed.

The servo amplifier is not
in Program mode.

There is a loose connec-
tion.

Solution

Pull out the E-stop button.

Check to see if:

❒ The blade guard is closed.

❒ Master Control relay

(MCR) has failed. Replace
relay.

Check connections and replace
if needed.

Check wiring between cutter
control and the relay.

Repair or replace the relay.

Check guard circuit, repair or
replace components.

Check servo, if necessary,
reboot main power.

Check wiring and tighten con-
nection.