Operation

n

1.02

Comfort Plus Commercial Hydronic

Operation

CONTROL PANEL

FIGURE 1

M

M

P

P

M

M

M

A

A

CONTROL PANEL

Operation of the Comfort Plus Commercial Hydronic system is automatic. All

operational functions are stored in its microprocessor in function locations and are

factory preset. If necessary, the installer can adjust them through the control panel.

(See Figure 1.)

Four-Digit LED Display

The four digit LED displays specific operating information. During an editing

process, the function locations and the values set in these locations are displayed for

viewing and adjusting purposes.

AM and PM Indicator Lights

The AM and PM indicator lights are only utilized if the Steffes Time Clock Module is being installed. With this

module installed, the system displays time on AM/PM intervals and the corresponding light flashes. The system

can be configured to display military time, in which case both the AM and PM

lights illuminate.

Mode (Edit) Button

Activates the editing menu for changing the operating information of the

system.

Up and

Down Arrow Buttons

Used to scroll up or down when viewing or changing

operating functions.

Interface Port

FOR SERVICE USE ONLY! Allows technician external access for updating software and troubleshooting.

OPERATING STATUS

The Comfort Plus Commercial Hydronic system is set to display various operating information as described below.

Press and release the up arrow to view this data.

Operating Mode - Indicates the current operating mode of the system.

C = Off-Peak (Charge) Time

P = On-Peak (Control) Time

A = Anticipated Peak Time

Outdoor Temperature -“O” followed by a number indicates current outdoor temperature.

Heat Call Status - Indicates the current heat call status being received from the room thermo-

stat. Refer to pages 3.11 and 3.12 for more information on heat call inputs.

Brick Core Charge Level - “CL” (charge level) followed by a number indicates the current

percentage of heat stored in the brick core. “CL:_” represents zero percent and “CL: F” repre-

sents a full core charge level.
Targeted Brick Core Charge Level - “tL” (target level) followed by a number indicates the

current percentage of brick core charge being targeted by the system. A display of “tL:_” indi-

cates a target level of zero percent and “tL: F” indicates a full core charge target level.

Load Control - Current demand (kW) divided by 10. A value of “d 75” is equal to a demand of

750kW.

A bar illuminates on the lower portion of

the display's second digit whenever one

or more heating elements are energized.

CAUTION

Editing operating

information may alter

the performance and

operation of the system.