Steffes 5140 Simplified Installation Guide User Manual
Quick reference installation guide, Comfort plus hydronic, Placement and clearances set-up
1
2
PLACEMENT AND CLEARANCES
SET-UP
Minimum Clearance Requirements
A Back and Right Side = 3 inches from
combustibles
B Front = 36 inches
C Top = 6 inches from combustibles
D Bottom = 1 inch from combustibles
E Left Side = 36 inches
Quick Reference Installation Guide
3
BRICK LOADING
1. Place system in desired location.
2. Adjust leveling legs.
3. Remove painted front panel of brick
storage cabinet.
4. Position element wiring harnesses
to avoid damage during brick
loading.
5. Position brick core temperature
sensor(s) to avoid damage during
brick loading.
6. Remove galvanized front panel.
7. Starting at bottom, lift and drape
insulation blankets over top of
system.
8. Remove front air channel by pulling
out at top.
9. Remove heating elements from
inside brick core cavity.
DO NOT extend leveling legs
more than one inch.
DO use and follow generally
accepted safety practices when
handling insulation material.
Equipment MUST be installed by
a qualified technician in accor-
dance with all applicable local,
state and national codes and
regulations.
Reference Owners and Installers
Manual for complete safety,
installation, and operation
instructions.
Starting at the back of the brick core cavity,
load bricks one row at a time using left side,
right side, center pattern. Place bricks with
grooved side facing up, notch facing forward,
and ridges on left and right.
Remove loose
debris from brick.
Brick rows MUST line
up front to back
and side to side.
Use half bricks in proper rows and in
correct positions. Back half of brick
MUST be installed in back rows. Front
half (notched brick piece) MUST be
installed in front rows.
If area available to install Comfort
Plus Hydronic system is less than 100
square feet, consult factory. If install-
ing in area with less than 400 square
feet, ventilation MUST be provided.
Temperature in area should be
maintained at or below 85
o
F.
TOP VIEW
A
B
A
E
D
A
C
FRONT VIEW
M
A
M
M
P
Manufactured in North America
COMFORT PLUS
HYDRONIC
Models 5120, 5130, 5140
Fro
nt o
f U
nit
Notch in Brick
HALF BRICK
5120: Load in row 5
5130: Load in row 4 and 8
5140: Load in row 6 and 12
CA
CA
CA
CA
CAUTION
UTION
UTION
UTION
UTION
WARNING
WARNING
WARNING
WARNING
WARNING