Order reference, Ec declaration of conformity – Pilz PNOZ s3 C 24VDC 2 n/o User Manual
Page 16
![background image](/manuals/647237/16/background.png)
PNOZ s3
Operating Manual PNOZ s3
21395-EN-10
16
Information
A safety function's SIL/PL values are
not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
ATTENTION!
It is essential to consider the relay's service life graphs. The relay outputs'
safety-related characteristic data is only valid if the values in the service life
graphs are met.
The PFH value depends on the switching frequency and the load on the relay output. If the
service life graphs are not accessible, the stated PFH value can be used irrespective of the
switching frequency and the load, as the PFH value already considers the relay's B10d val-
ue as well as the failure rates of the other components.
Order reference
Order reference
Product type Features
Terminals
Order
no.
PNOZ s3
24 V DC
Screw terminals
750 103
PNOZ s3 C
24 V DC
Spring-loaded terminals 751 103
EC declaration of conformity
This product/these products meet the requirements of the directive 2006/42/EC for machin-
ery of the European Parliament and of the Council. The complete EC Declaration of Con-
formity is available on the Internet at www.pilz.com/downloads.
Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfil-
dern, Germany