beautypg.com

Pilz PSEN in1p User Manual

Page 11

background image

- 11 -

1380451083

Beispiel:
Fehlercode 1,4,1:
Die LED "Safetygate" oder "Input" blinkt

3-mal kurz
Pause
1-mal für je eine Sekunde
Pause
4-mal für je eine Sekunde
Pause
1-mal für je eine Sekunde
3-mal kurz

Example:
Error code 1,4,1:
"Safetygate" or "Input" LED flashes

3 times, briefly
Pause
Once for one second
Pause
4 times, for one second each
Pause
Once for one second
3 times, briefly

Exemple :
Code d'erreur 1,4, 1 :
La LED « Safety Gate » ou « Input » clignote

3 fois rapidement
Pause
1 fois pendant une seconde à chaque fois
Pause
4 fois pendant une seconde à chaque fois
Pause
1 fois pendant une seconde à chaque fois
3 fois rapidement

1406525451

I Code für Fehlermeldung
II Code für 1. Ziffer
III Code für 2. Ziffer
IV Code für 3. Ziffer
V Wiederholung Code für Fehlermeldung

I Code for error message
II Code for 1st digit
III Code for 2nd digit
IV Code for 3rd digit
V Code for error message repeated

Code I pour message d'erreur
Code II pour le 1er chiffre
Code III pour le 2ème chiffre
Code IV pour le 3ème chiffre
Répétition du code V pour le message d'erreur

Fehlercode
dezimal

Anzahl der Blinkimpulse

Beschreibung

Abhilfe

1,4,1

3x kurz – 1x lang – 4x lang –
1x lang – 3x kurz

Im Systemhochlauf ist mindestens einer der beiden
Sicherheitsausgänge 12 und 22 nicht spannungsfrei

Verdrahtung der Klemmen 12 und 22
prüfen, Verdrahtungsfehler beheben

1,12

3x kurz – 1x lang – 12 x lang
– 3x kurz

Im Betrieb Kurzschluss zwischen dem Sicherheits-
ausgang 12 und 0 V DC

Verdrahtungsfehler an Klemme 12
beseitigen

1,6,3

3x kurz – 1x lang – 6x lang –
3x lang – 3x kurz

Im Betrieb Kurzschluss zwischen dem Sicherheits-
ausgang 12 und 0 V DC

Verdrahtungsfehler an Klemme 12
beseitigen

1,13

3x kurz – 1x lang – 13 x lang
– 3x kurz

Im Betrieb Kurzschluss zwischen dem Sicherheits-
ausgang 22 und 0 V DC

Verdrahtungsfehler an Klemme 22
beseitigen

14

3x kurz – 14x lang – 3x kurz

Im Betrieb Kurzschluss zwischen dem Sicherheits-
ausgang 12 und 24 V DC

Verdrahtungsfehler an Klemme 12
beseitigen

15

3x kurz – 15x lang – 3x kurz

Im Betrieb Kurzschluss zwischen dem Sicherheits-
ausgang 22 und 24 V DC

Verdrahtungsfehler an Klemme 22
beseitigen

1,4,2

3x kurz – 1x lang – 4x lang –
2x lang – 3x kurz

Im Betrieb Kurzschluss zwischen dem Sicherheits-
ausgang 22 und 24 V DC

Verdrahtungsfehler an Klemme 22
beseitigen

Error code
decimal

Number of flashes

Description

Remedy

1,4,1

3x short – 1x long – 4x long –
1x long – 3x short

At least one of the two safety outputs 12 and 22 have
voltage applied during system run-up

Check the wiring of terminals 12 and
22, rectify the wiring error

1,12

3x short – 1x long – 12x long
– 3x short

During operation, short circuit between safety output
12 and 0 VDC

Rectify wiring error at terminal 12

1,6,3

3x short – 1x long – 6x long –
3x long – 3x short

During operation, short circuit between safety output
12 and 0 VDC

Rectify wiring error at terminal 12

1,13

3x short – 1x long – 13x long
– 3x short

During operation, short circuit between safety output
22 and 0 VDC

Rectify wiring error at terminal 22

14

3x short – 14x long – 3x short During operation, short circuit between safety output

12 and 24 VDC

Rectify wiring error at terminal 12

15

3x short – 15x long – 3x short During operation, short circuit between safety output

22 and 24 VDC

Rectify wiring error at terminal 22

1,4,2

3x short – 1x long – 4x long –
2x long – 3x short

During operation, short circuit between safety output
22 and 24 VDC

Rectify wiring error at terminal 22

Code d'erreur
décimal

Nombre d'impulsions clig-
notantes

Description

Remède

1,4,1

3 x court – 1 x long – 4 x long
– 1 x long – 3 x court

Au démarrage du système, au moins une des sorties
de sécurité 12 et 22 n'est pas libre de potentiel

Vérifier le câblage des bornes 12 et
22, supprimer le défaut de câblage

1,12

3 x court – 1 x long – 12 x
long – 3 x court

En fonctionnement, court-circuit entre la sortie de
sécurité 12 et le 0 V DC

Supprimer le défaut de câblage sur la
borne 12

1,6,3

3 x court – 1 x long – 6 x long
– 3 x long – 3 x court

En fonctionnement, court-circuit entre la sortie de
sécurité 12 et le 0 V DC

Supprimer le défaut de câblage sur la
borne 12

1,13

3 x court – 1 x long – 13 x
long – 3 x court

En fonctionnement, court-circuit entre la sortie de
sécurité 22 et le 0 V DC

Supprimer le défaut de câblage sur la
borne 22

14

3 x court – 14 x long – 3 x
court

En fonctionnement, court-circuit entre la sortie de
sécurité 12 et le 24 V DC

Supprimer le défaut de câblage sur la
borne 12

15

3 x court – 15 x long – 3 x
court

En fonctionnement, court-circuit entre la sortie de
sécurité 22 et le 24 V DC

Supprimer le défaut de câblage sur la
borne 22

1,4,2

3 x court – 1 x long – 4 x long
– 2 x long – 3 x court

En fonctionnement, court-circuit entre la sortie de
sécurité 22 et le 24 V DC

Supprimer le défaut de câblage sur la
borne 22

I

IV

III

II

V