LogicPLUS-S Two-Wire Controller
4
4
Field Wire Outputs
4
4
Minimum Wire Size
14 gauge
14 gauge
Maximum Wire Run
12,000 Feet
12,000 Feet
Maximum Number of Receivers
80
128
Receivers Programmable
and Re-Programmable
Yes
Yes
On Board Receiver
Programming
Capability
Yes
Yes
Remote Receiver
Programming
use LP-HHRP
Yes
Yes
Security Password
Yes
Yes
enclosure:
Box - Stainless steel, locking, wall or pedestal mount.
Pedestal – Stainless steel
See diagram page 45 for box and pedestal dimensions.
input Power:
110VAC, 240VAC 50/60Hz
Solar 12V DC
Grounding:
Enclosure grounded to utility ground. SPD/Output board grounds with 8 foot ground rod.
See diagram page 35, 36
Surge/Lightning Protection:
Controller Surge Protection is provided by an assembly mounted below the controller panel. This
board and its components are like a sophisticated fuse. It will blow in an attempt to save the main
circuit board from destruction by line surges mainly created by lightning. It is connected to the
main board with a simple cable for easy removal for testing and replacement if necessary.
See diagram page 34
Field Surge Protection is provided by the use of LP-SPD-F devices. Designed to be installed in
valve boxes every 200-300 feet and attached to a ground rod. Rod is customer supplied.