LogicPLUS-S Two-Wire Controller

23

Position 10

| | Semi / Manual / Program / Master Clear | | Current Monitoring Special Function

Semi- use set 1 to choose the program you want to activate for one cycle, use set 2 to activate that

program ON. Leave the dial in number 10 position.

[Rotating the dial will cancel the program.]

Set 5 will activate the Current Monitoring feature.
note: 30 minutes after the conclusion of the selected program the controller will automati-

cally revert to the “RUn” condition, without putting the dial back to “Run.”
Manual
— Press set 3 to activate manual mode the display will change, use set 1 to choose the

specific valve number to be operated manually for a predetermined time, use set 2 to set amount of

hours to run, use set 3 to set amount of minutes, use set 4 to tell the controller whether or not you

want the master valve A, B, C, and pump on during this manual operation. Valve will immediately be

activated for that period of time. Use set 5 to activate the Current Monitoring feature. Leave the dial

in number 10 position.

[Rotating the dial will cancel the program.] At the conclusion, the controller

will go back to “RUN” mode without turning the Dial back to the “RUN” position. You can activate up

to 8 valves at the same time in manual mode.

note: 30 minutes after the conclusion of the selected valves the controller will automatically

revert to the “RUn” condition.

Position 10