Hit Products LogicPLUS S 42/128 User Manual
Page 20

LogicPLUS-S Two-Wire Controller
20
20
note: Program 6 can be sensor activated, such as a temperature sensor. The terminals
for remote operation are located on the terminal board and marked pr6trg (program 6 trig-
ger). Program the amount of run times per valve in program 6, do not put in a start time,
make sure the program is On in position 8 and whether or not the master should run with
program 6.
Program the amount of loop time in position 7. When the remote sensor activates and closes
the contacts for more than 30 seconds, program 6 will operate for the looping time programmed.
If for any reason the remote sensor contact opens during the looping cycle, the looping cycle will
continue until the programmed time is completed. The sensor must open and close the contacts
to operate the looping cycle a second time. If, for any reason, the contacts open and close dur-
ing the pre-programmed length of looping, the looping program will reset at that time and start
over again.
Position 7 | | Looping Program No. 6 | | Function Button- Security Password
Position 8 | | Program / Master Valves ON/OFF | | Pump Start | | Water Budget 0%-250%