Thermostat Sensor

11,900 Ohms @ 70°F, ECO opens @ 201°F Max., ECO close @ 100°F Min.

Thermostat Board

Max temp 180°F, Min temp 91°F, 24VAC, 60Hz max.

Hot Surface Igniter

120VAC, 30-120 ohms @ room temperature.

Flame Sensor Output

Minimum 1 micro amp, Typical range 4 to 7 micro amps.

Temperature Dial

Min. set point 5400-6600 ohms, Max set point 0-50 ohms.

Ignition Module

See “Sequence of Operation, for models starting with CF serial and later”

Gas Valve

Negative regulation, 24 VAC, ½" PSI max., 4.5" W.C. Minimum running inlet.

Transformer

120VAC primary, 24VAC secondary, 40VA.

Vent Safety Switch

Normally closed, opens @ 350°F, manual reset.

Intake Pressure Switch

“CF” serial number or

later

Not required.

Blower

120VAC, 60Hz, .6-1 amps, 6400 RPM.

Exhaust pressure switch

serial numbers prior to

“CF”

24VAC, normally open, closes on pressure increase as follows

Note 1:

+2.58" W.C.

EF(60,100)T199

+1.50" W.C.

EF100T150 (see note 2)

+1.22" W.C.

EF60T150, EF100T250

+2.08" W.C.

EF60T125

+0.55" W.C.

EF100T300 (see note 3)

Note 2: +5.6" W.C. on serials prior to AH5039107

Note 3: +0.8" W.C. on serials prior to AK5288269

Power supply

Dedicated 120 VAC, 60 Hz, 15A, GFI

Approved Gas Type

Natural or Propane. Unit must match gas type supplied.

Venting System

Power vent, balanced direct vent or unbalanced direct vent. See vent tables on page 7

Approved Vent Materials PVC or CPVC

Gas Supply

Minimum 1" NPT for EF100T399, all others ¾" NPT

(schedule 40 black iron pipe recommended)

Minimum Clearance

for Servicing

18" from top, 24" from front, 4" sides and rear.

Maximum Water Supply

Pressure

150 PSI

Gas Pressure (

Nat & L.P.

) 14.0" W.C. maximum static, 4.5" W.C. minimum running (recommend 7.0" W.C. min running)

Combustion Levels

CO2: 10-11%, CO: less then 0.04 percent (400 PPM) air free

Intake Pressure Switch

serial numbers prior to

“CF”

24VAC, normally closed, opens on vacuum increase @ -1.20 W.C.

Blocked Vent Pressure

Switch “CF” serial

number or later

24VAC, normally closed, opens when pressure increases to +2.70 W.C.

7