Page 57

background image

Reset button

Does blower

energize?

N

Sequence of operation:

The blocked vent pressure switch monitors the pressure in the exhaust tube. The switch contacts are normally closed and will

not open unless there is a blockage in the exhaust venting or terminal (snow, ice, debris). If the blocked vent pressure switch

contacts open after the thermostat initiates the blower, the blower will remain on for to 5 minutes waiting for the contacts to close.

If the contacts remain open, the blower will stop and the PURGE LED will flash for hot surface ignition models, or error code 29

will display for direct spark ignition models.

Hot Surface Ignition Models:

Check PURGE LED status.

Direct Spark Ignition Models:

Check control display

Y

Refer to

“Check Collector Pressure”

(see next page)

Check blower for proper

operation (see “Blower

Testing and Replacement”)

Is blower OK?

N

On within 5 minutes?

Pressure switch is OK.

Y

Y

Safety Circuit Trace

LED Status

Only power LED is on, or

Purge LED flashing.

Error Code 29 or 26

(Direct Spark Ignition

Models)

Blocked Vent Pressure Switch Testing and

Replacement for serial number “CF” and later

N

WARNING

120 volt potential exposure. Use caution

making voltage checks to avoid personal injury.

Flashing after 5 minutes?

Error code 29 again?

Call for technical

support.

Correct blower problem

(see “Blower Testing and

Replacement”)

N

Y

Note: HOT SURFACE IGNITION MODELS

ONLY - The blocked vent pressure switch

must be used with the revised ignition control,

identified with a yellow label.

Heater side

harness

Control side

harness

57

Y

Is there continuity

Through GREY

wire leads of heater side

safety circuit harness?

(see photo below)

N

Y

Is there continuity

through RED

wire leads of heater side

safety circuit harness?

(see photo below)

N

Safety Circuit OK,

(see “Blower Testing

& Replacement”)

Replace exhaust

pressure switch (see

“Exhaust Pressure

Switch Replacement

Procedure”)

Replace vent safety

switch.

(see “Vent Safety

Switch Replacement

Procedure”)

Call technical

support.

Y

N

Depress reset

button on vent

safety switch. Is

there continuity

across high limit

switch?

(see photo below)

Check PURGE LED status

on ignition module,

Flashing after 45 seconds?

Does heater

function?

Verify proper

switch operation.

(see “Vent Safety

Switch Testing and

Replacement”)

N

Y

Y

WARNING

Make sure exhaust collector compartment is not

overheating (350°F) before resetting vent safety

switch. If there is evidence the collector compartment

is overheating, CALL TECHNICAL SUPPORT.

57