Transformer Replacement Procedure

Step 4.

For Hot Surface Ignition models, refer to ignition module illustration below, Disconnect wire harness

P1 labeled “PRIMARY” and P2 labeled “SECONDARY” from ignition module.

Step 5.

For Hot Surface Ignition models,

Disconnect secondary leads (blue &

yellow wire) from thermostat board.

Note the blue wire is connected to

24 volt “HOT” terminal. (see photo below)

For Direct Spark Ignition models,

Disconnect primary leads (black & white) and

secondary leads (blue & yellow) from the

transformer. (leads are different sizes to

prevent interchanging)

Step 6.

Remove the 2 screws ( short Phillips screw driver) holding the transformer in place and

remove transformer from control panel. (see photo below)

Step 7.

Install new transformer and secure in

place with screws from step 6.

Step 8.

For Hot Surface Ignition models,

Reconnect wire harness P1 & P2,

connections are non-interchangeable

to insure proper reconnection.

For Direct Spark Ignition models,

Reconnect primary and secondary wires to transformer.

(leads are different sizes to prevent interchanging)

Step 9.

For Hot Surface Ignition models,

Reconnect blue & yellow wire leading from the

P2 connection on ignition module to

thermostat board. Note the blue wire must connect to the 24

volt “HOT” terminal. (see photo at right)

Step 1.

Position main power switch to “OFF”.

Step 2.

Disconnect (Unplug) water heater

from 120 Volt power source.

Step 3.

Un-latch & remove surround cover from

top of water heater.

Step 10. Restore 120 volt power supply to water heater and

confirm proper operation following the lighting

instructions on the lighting instruction label or the

lighting instruction located in the installation and

operating instruction manual.

Step 11. Replace surround cover on top of water heater.

WARNING

120 volt potential exposure. Isolate the

appliance and reconfirm power is

disconnected using a multi-meter.

Step 3

Disconnect harness

“P1” & “P2”

from ignition module

Ignition module

Step 5

Disconnect blue & yellow wire from

thermostat board. Note blue wire is

connected to 24 volt “HOT” terminal.

Thermostat

board

Step 6

Remove transformer

mounting screws

24 volt common,

yellow wire connection

24 volt Hot,

blue wire connection

Thermostat

board