Bradford White EF-100T-399-3X User Manual
Page 36
Condition: Water Heater Not Operating
Display shows error code “65”
High Water Temperature (over 200 °F)
(Continued from previous page)
Once cause of overheating condition has been diagnosed
and corrected, the control may be reset
Reconnect and switch on power to the water heater.
Enter service mode on the water heater display (see illustration)
Press button under “Lockout Reset” and hold for 3 seconds.
Set thermostat to the desired setting.
Water heater will start.
Monitor temperatures for one complete heating cycle making
sure the maximum tank temperature remains well below 200 °F
WARNING
Do not operate water heater without
verifying that the overheating
condition has been corrected.
36
Serial Numbers including and AFTER GB13006174 and ALL EFR models
36