Thermostat Potentiometer Replacement Procedure

Step 4.

Loosen set screw of adjusting

knob (small blade screw driver)

and remove adjusting knob

from potentiometer. (see photos at right)

Step 5.

Remove retaining nut (½" wrench)

and washer from potentiometer.

(see photos at right)

Step 6.

From inside of surround area, remove potentiometer

with gasket from side of surround. Notice how indexing

tab on potentiometer assembles into locating hole of

surround. (see photos below)

Step 7.

Disconnect potentiometer wire leads.

(see photo at right)

Step 8.

Install new potentiometer with gasket into side of surround. Be sure to assemble with

indexing tab inserted into locating hole on side of surround (see photos above).

Step 9.

Reconnect wires to potentiometer. Note: Wire leads are interchangeable with either wire.

Step 10. Restore 120 volt power supply to water heater and confirm proper operation following

the lighting instructions on the lighting instruction label or the lighting instruction located

in the installation and operating instruction manual.

Step 11. Replace surround cover on top of heater.

Step 1.

Position main power switch to “OFF”

Step 2.

Disconnect (unplug) water heater from

120 volt power source.

Step 3.

Un-latch and remove top surround cover

from top of heater.

WARNING

120 volt potential exposure. Isolate the

appliance and reconfirm power is

disconnected using a multi-meter.

Temperature

Adjusting Knob

Indexing

Tab

Locating

Hole

41

Loosen set screw

with small blade

screw driver

Remove

retaining nut

Potentiometer

Wire Leads

41