Hot Surface Ignition Models:

Are safety circuits in normal position?

Direct Spark Ignition Models:

Is collector high limit switch and

pressure switch in normally closed

position?

Does blower

energize?

(For Direct Spark

Ignition models,

ensure control display

shows “Heating”, raise

temperature setpoint if

necessary)

Is there 120VAC

across the white and

black wires at the

blower?

(see photo at right)

Replace blower.

(see “Blower

Replacement

Procedure”)

Y

N

Refer to ignition module/

control board illustration.

Hot Surface Ignition Models:

Is there 120VAC between

P5(1) and P5(3)?

Direct Spark Ignition Models:

Is there 120VAC between

P7(5) and P7(3)?

Repair/replace

wire harness.

Y

Replace ignition module/

control board.

Y

N

N

Y

N

N

Is there 120VAC

across the white and

black wires at the

terminal block ?

Hot Surface Ignition

Models ONLY:

Refer to ignition

module, is there 24

VAC between

P3(7)

and ground?

Y

N

Thermostat not

calling for heat.

(see “Thermostat

Circuit Testing”)

Correct safety circuit problem per

safety circuit trace

(section “Blocked Vent Pressure

Switch Testing”).

Y

Y

Is there 120VAC

across the white and

black wires at the

terminal block ?

(see photo at right)

N

N

Refer to ignition module/control board

illustration.

Hot Surface Ignition Models:

Is there 120VAC between

P5(1) and P5(3)?

Direct Spark Ignition Models:

Is there 120VAC between

P7(5) and P7(3)?

Y

Replace

ignition module/

control board.

Call technical

support.

Check amp draw through

BLACK wire lead of blower

motor. Is there .6 to 3.0

amps?

Replace blower.

(see “Blower Replacement

Procedure”)

N

Y

Is Blower wheel secured to

blower motor shaft?

N

Y

Determine

power

source

problem

and

correct

52

Black wire leading to

blower motor looped

through amprobe.

120VAC check at

Terminal Block

Checking for 120VAC

(Black & White Wires)

IGNITION MODULE

HOT SURFACE IGNITION MODELS

1

2

3

8

6
5
4

3

1

1

2

1

4

1

3

3

2

1

1

5

3

P2

P4

P5

P7

P3

CONTROL BOARD

P10

P9

J1

DIRECT SPARK IGNITION MODELS