Ignition Module Replacement Procedure

Step 1.

Position main power switch to “OFF”.

Step 2.

Disconnect (Unplug) water heater

from 120 Volt power source.

Step 3.

Un-latch & remove surround cover from top of water heater.

Step 4.

Locate Ignition module on control panel inside surround area.

(see photo below)

Step 7.

Install new ignition module and secure in place with screws from step 6.

Step 8.

Carefully reconnect all wire harness connection to ignition module. Connection are

non-interchangeable to insure proper reinstallation.

Step 5.

Carefully disconnect all wire harness connection to ignition module. Connection are

non-interchangeable to insure proper reinstallation.

Step 6.

Remove the 3 screws (Phillips screw driver) holding the ignition module in place and

remove ignition module from control panel.

Step 9.

Restore 120 volt power supply to water heater and confirm proper operation following the

lighting instructions on the lighting instruction label or the lighting instruction located in

the installation and operating instruction manual.

Step 10. Replace surround cover on top of water heater.

Note: Replacement hot surface

ignition module works on all EF

models prior to and later than “CF”

serial numbers. Direct spark ignition

models use a different control board

(detailed in following section).

Ignition Module

located on control panel

WARNING

120 volt potential exposure. Isolate the

appliance and reconfirm power is

disconnected using a multi-meter.