ERROR CODE

DEFINITION

SERVICE ACTION

POSSIBLE PARTS NEEDED

No LED

No pilot light / Heater not in operation

Follow lighting instructions

1) None

on the water heater

One flash & three second pause

Knob in pilot position or thermostat satisfied

None

1) None

LED Strobe (two quick flashes)

Thermostat calling for heat

None

1) None

& three second pause

LED on continuously

Control knob turned to the off position

Wait for LED to go off before relighting

1) None

Two flashes

Weak pilot signal detected

Verify pilot is lit

1) Pilot assembly

& three second pause

Check thermopile voltage output

2) Gas valve

Check wire connections at gas valve

Three flashes

Gas valve has not seen temp rise

Check temp probe ohms

1) Gas valve cover w/ temp

& three second pause

in proper amount of time

Verify water is not flowing

probe

Four flashes

High tank temperature

Check temp probe ohms

1) Gas valve cover w/ temp

& three second pause

Check water temperature

probe

Five flashes

Thermostat sensor fault

Check temp probe ohms

1) Gas valve cover w/ temp

& three second pause

Check water temperature

probe

Six flashes

Water leak detected by the accessory module

Refer to trouble shooting

1) Refer to troubleshooting

& three second pause

(if installed)

for the accessory module

for the accessory module

Seven flashes

Gas valve fault

Reset gas valve; if problem

1) Gas valve

& three second pause

persists replace gas valve

Eight flashes

Pilot remains lit while the control knob

Check gas pressure

1) Gas valve

& three second pause

is in off position

Replace gas valve

2) Gas valve cover w/ temp

probe

NOTE:

Check all wire connections
Check gas inlet and manifold gas pressure
Check for grounding connections

Technical Support

800-334-3393

ICON - Atmospheric Vent Water Heaters