Resetting Error Codes

For models with Honeywell Integrated Control

WARNING

The following procedure is for service and installation personnel only. Resetting lockout

conditions without correcting the malfunction can result in a hazardous condition.

If an error code is displayed (except for #4, low flame sense current), the water heater will be in a “lockout condition”

with the water heater display showing the error code number and “Service Needed” in the status section of the

display window. Error codes 62 (maximum number of retries detected) and 63 (maximum number if ignition

recycles detected) are “Soft Lockouts” in which the control can be reset in the “User Mode” by pressing the lower

right button under “Lockout Reset” shown in the lower right portion of the display. The control will also go through 3

attempts to relight the burners every hour in the soft lockout condition.

All other error codes will put the water heater into a “Hard Lockout” condition, in which the water heater will not

operate and cannot be reset in the “User Mode”. To reset a hard lockout, first enter the “Service Mode” described

earlier by pressing both the “Temperature Up” and “Select Buttons” at the same time for 3 seconds. Then press the

lower right button under “Lockout Reset” in the water heater display and hold for 3 seconds.

Lockout RESET

SELECT

Status Service needed

%

Error Code Shown in

Water Heater Display

Press for 2 seconds

&

SELECT

SET

Status Service Needed

%

SELECT

Lockout RESET

Status Service Needed

Error Code Shown in

Water Heater Display

Step 1: Press for 3 seconds

to enter service mode.

Step 2: Press for 3 seconds to

reset control in service mode.

Resetting Error Codes in Hard Lockout Condition