beautypg.com

Exhaust pressure switch replacement procedure – Bradford White EF-100T-399-3X User Manual

Page 56

background image

Exhaust Pressure Switch Replacement Procedure

Step 1.

Position main power switch to “OFF” position.

Step 2.

Loosen adhesive backed rubber escutcheon from service panel access cover

and slide escutcheon back along exhaust pipe to allow for removal of cover.

Step 3.

Remove screws from service panel access cover

(¼" nut driver) and remove cover from heater.

(see photos at right)

Step 4.

Disconnect silicone tubing and wire leads from

pressure switch. (see photos at right)

Step 5.

Remove pressure switch mounting screws

(5/16" wrench) and remove pressure switch.

Step 6.

Assemble new pressure switch to heater using

screws from step 5.

Step 7.

Reconnect wire leads. Note: wire leads are

interchangeable with either terminal.

Step 8.

Reconnect silicone tubing to pressure switch

as follows:

a) Exhaust pipe tubing connects to

negative (-) side of switch

identified by the (-) symbol

located on switch.

b) Exhaust collector tubing connects

to positive (+) side of switch

identified by the (+) symbol located

on the switch.

Step 10. Reinstall service panel access cover and

rubber escutcheon.

Exhaust Pressure Switch Testing and Replacement

For serial numbers prior to “CF”

Step 9.

Restore 120 volt power supply to water heater

and confirm proper operation following the

lighting instructions on the lighting instruction

label or the lighting instructions located in the installation

and operating instruction manual.

Exhaust pipe

pressure tap location

Exhaust collector

pressure tap location

(serial numbers prior

to “CF”)

Example of switch

showing positive

side identifier

56

Rubber

escutcheon

Pressure switch

mounting screw

5/16 hex head

Silicone tubing

Wire leads

56

This manual is related to the following products: