SYSTEM OPERATION

Initial Start-Up

When power is applied to the unit, the control will briefly

display all symbols, and the Snow Flake symbol will be

displayed (if unit is calling for cooling). There may be a

brief delay prior to the evaporator fan turning on. When

the evaporator fan is activated the Fan symbol will

be displayed. The temperature control feature for the

evaporator fan is a feature applicable to WhisperKOOL.

This is the Advance Product Safety Technology (APST),

which ensures that in the possible event of a cooling

deficiency, the heat from the indoor fan will not raise the

temperature of the wine cellar, which could otherwise

have an adverse effect on the wine-aging process.

Normal System Cycle

The FON function is an adjustable feature which allows

the customer the convenience of reintroducing some of

the humidity removed by the fan coil during the cooling

process. The FON Function is a feature that controls the

evaporator fan operation once the set point has been

reached. All units are shipped with the set point of 55°F

and a differential of 1°F. All units come with this feature

turned off. If low humidity is a problem an increase in this

setting will raise the humidity level. The FON function is

one of the many Customer Preference Selection features

that allow the customer the ability to fine-tune the

controls.

Anti-Short Cycle

The Anti-Short Cycle ensures that the unit will remain off

for a period of 5 minutes after the unit has reached the

set point to allow the pressure in the refrigeration system

to equalize prior to starting the compressor.

Anti-Frost Cycle

The Anti-Frost Cycle is a precautionary measure, as icing

or frosting of the coil does not occur during normal

operation. The system will go through a defrost cycle

every 4 hours. During the defrost cycle, the indoor fan

will provide airflow across the indoor coil, which will

evaporate any frost accumulation.

Low Ambient Conditions

If the condensing unit is installed outside (which will

allow the condenser to be exposed to low ambient

temperatures), the condenser fan may cycle on and

off. The purpose of the fan cycling is to maintain

the system high side pressure, which will ensure an

adequate refrigeration process. The fan cycling process is

accomplished by way of a Johnson Control or fan cycling

switch attached to the condensing unit.

Bottle Probe Failure Protection In the event that a

bottle probe should fail, the APST (Advance Product

Safety Technology) will automatically transition the

Refrigeration Compressor cycles to a predetermined time

series (based on detailed laboratory testing), which will

ensure that the product is kept within the safe range.

Remote Keypad (standard on ducted units)

The remote keypad is designed to give the user the

ability to monitor and change cellar conditions when the

evaporating unit is placed in a remote location outside of

the cellar.