1"
MIN.
1/2"
FS-43
(#12 X 3/4" PPH)
SEAL FACE & SIDES
OF SHEAR BLOCK
MAXIMUM END REACTION
625 Lbs.
SEAL FACE, SIDE &
MARRY WITH
MULL CAP SEAL
CAP SEAL ALL
FASTENERS IN
GLAZING POCKET
HP175-FP-59 MULL CAP
MODIFIED, LOCATE AT
EACH END OF HEAD & SILL
FS-202
(#8 x 1/2" PPH)
BED MULL CAP
IN SEALANT
DRILL .149 (#25 BIT)
CLEAR HOLE
11/16"
11/16"
CUT D.L.O.
SEALANT PROCEDURES
FOR JAMBS & MULLS
H P - 1 7 5 / 2 2 5 I N S T A L L A T I O N M A N U A L