Hp-175-225 10, Integral diverter horizontal glazing details – Oldcastle BuildingEnvelope HP-175 User Manual
Page 10

NHP-5A GASKETS.
CUT HORIZONTAL
GASKETS D.L.O.
+ 1/4" PER FOOT.
MARK LOCATION OF EACH
GLAZING CLIP PRIOR TO
INSTALLING FACE CAPS.
HP-36 TEMPORARY
CLIPS. SLIDE ONTO
GLAZING CLIPS.
SETTING BLOCK MAY BE
MODIFIED TO FIT VARIOUS
GLASS THICKNESSES. TEAR
BLOCK FOR DESIRED SIZE.
5/8"
1/4"
1"
SEAL INTERIOR CORNERS OF
GASKETS AS SHOWN. FORCE
SEALANT INTO JOINT BETWEEN
GASKETS.
GLAZING NOTE:
GLAZE SYSTEM FROM BOTTOM
TO TOP. INSTALLING DIVERTERS
TO HORIZONTAL ABOVE AS YOU
PROCEED UP BUILDING.
HP-17
SETTING
BLOCK
GLASS SIZING
HP-175 = D.L.O. + 3/4"
HP-225 = D.L.O. + 1"
NHP-5A GASKETS
VERTICAL GASKETS TO
RUN THROUGH AND ADD
1/4" PER FOOT
CAUTION:
BE CERTAIN THAT GLASS IS PLACED
FIRMLY AGAINST INTERIOR GASKET
BEFORE SETTING ON BLOCKS. GLASS
BREAKAGE CAN OCCUR AT OR NEAR
SETTING BLOCKS DUE TO THE WEIGHT
NOT ALLOWING THE GLASS TO MOVE
TOWARD INTERIOR GASKET.
LUBRICATING THE TOP OF THE
SETTING BLOCK WILL HELP INSURE
PROPER SETTING OF GLASS
INTEGRAL DIVERTER HORIZONTAL
GLAZING DETAILS
H P - 1 7 5 / 2 2 5 I N S T A L L A T I O N M A N U A L
10