Hp-175-225 27, Inside 90° corner detail – Oldcastle BuildingEnvelope HP-175 User Manual
Page 27

HP-10463
ATTACH W/ FS-6
(#10 X 3/4 PPH)
@ 12" O.C.
BED IN SEALANT
WATER DIVERTER
HP-10443
"A"
"A"
SECT "A-A"
ATTACH ANGLE TO
CORNER CLOSURE
AT HEAD & SILL
FORMED ALUM. CORNER
COVER. ATTACH W/
FS -7 (#10 X 3/4" PFH)
@ TOP & BOTTOMOF
COVER (MIN.)
NOTE:
REFERNCE STANDARD MULL
DRAWINGS FOR ADDITIONAL
INFORMATION.
HP-10462
AN-1 ANGLE
ATTACH W/ FS-6 @ 18" O.C.
DIVERTER BRIDGE
MODIFY AS SHOWN.
SEA LANT NOT SHOWN
FOR CLARITY. *
NOTE:
USE TYPICAL MULL CAPS AND
MODIFY SIMILAR TO JAMB CAPS.
(SEE SHEET #6)
THEN MARRY SEAL ACROSS MULL
CAPS AND ANGLES ATTACHED TO
CORNER CLOSURE.
* USE STANDARD DIVERTER BRIDGE
AT HORIZONTALS AND MODIFY AS
SHOWN IN DETAIL ABOVE. SEAL PER
STANDARD BRIDGE DETAILS ON SHEET 9.
HP175-FP-65
END CAP
INSIDE 90°
CORNER DETAIL
H P - 1 7 5 / 2 2 5 I N S T A L L A T I O N M A N U A L
27