Hp-175-225 24, Outside 90° mullion assembly – Oldcastle BuildingEnvelope HP-175 User Manual
Page 24

1"MIN.
1 1/4"
1 7/32"
HP175-FP-57 MULL CAP
@ SILL & HEAD
ATTACH W/ FS-23
(#6 X 3/8" PPH)
BED IN SEALANT
FS -43 (#12 X 3/4" PPH)
SET HORIZONTAL IN
SEA LANT AT MULL CAP
SEA L FACE, TOP
& BOTTOMOF
SHEAR B LOCK
CUT SILL & HEAD
DLO- 1/16"
CUT HORIZ. DLO
INTERIOR MULL
COVER
45˚
FAB NOTE:
SQUARE CUT HORIZONTAL
TO FACE OF GASKET RACE
ANDMITER AT 45˚.
HP-10459
ATTACH W/ FS-55
@ 18" O.C.
OUTSIDE 90° MULLION
ASSEMBLY
H P - 1 7 5 / 2 2 5 I N S T A L L A T I O N M A N U A L
24