4 fru information, 1 module current requirements, Fru information – Kontron AT8242 User Manual
Page 79
63
www.kontron.com
4.4.4
FRU Information
Table 4-43:Board Information Area
Table 4-44:Product Information Area
4.4.4.1
Module Current Requirements
Each NPU engine is seen as a virtual AMC, with its own power and reset domain. Even though they are not
physically extractable, the Module Current Requirements Record is present in FRU data as to insure proper
compatibility with the AMC.0 R2.0 specification.
Table 4-45:Module Current Requirements
Board Information Area
Board Mfg Date
Programmed with manufacturing date
Board Mfg
Kontron
Board Product
AT8242
Board Serial
Programmed with serial number
Board Part Number
Programmed with part number
Board FRU ID
FRU5311MMC-xx
Board Extra
MAC=xx:xx:xx:xx:xx:xx/64
Product Information Area
Product Manufacturer
Kontron
Product Name
AT8242
Product Part Number
Programmed with part number
Product Version
Programmed with board revision
Product Serial
Programmed with serial number
Product FRU ID
FRU5311MMC-xx
Field
Value
Record Type ID
C0h
Record Format Version
02h
Record Length
*Calculated
Record Checksum
*Calculated
Header Checksum
*Calculated
Manufacturer ID
00315Ah (PICMG Record ID)
PICMG Record ID
16h (Module Current Requirements)
Record Format Version
00h
AMC Module Current Draw
22h (3.4 Amps at 12V => 40.8 Watts)