Kontron AT8242 User Manual
Page 61

45
www.kontron.com
47
FRU3 IPMBL State
Discrete
IPMB-L branch from FRU3 fault detection sensor
Sensor type = C3h OEM (Kontron OEM IPMB-L link state)
Event Reading type code = 6Fh Sensor specific, offset 2 and 3 are used
See OEM table, Sensor type code C3h for sensor definition
48
FRU Over Icc
Discrete
FRU Over Current Sensor
Sensor type = CBh OEM (Kontron OEM FRU Over Current)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code CBh for sensor definition
49
FRU Sensor Error
Discrete
FRU Error during external FRU Sensor discovery
Sensor type = CCh OEM (Kontron OEM FRU sensor error)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code CCh for sensor definition
50
FRU Pwr Denied
Discrete
FRU Power Denial Detection
Sensor type = CDh OEM (Kontron FRU Power denied)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code CDh for sensor definition
51
FRU MngtPwr Fail
Discrete
FRU Management Power Fail
Sensor type = D2h OEM (Kontron FRU Management Power Fail)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code D2h for sensor definition
52
FRU0 Agent
Discrete
FRU Information Agent - FRU0 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition
53
FRU1 Agent
Discrete
FRU Information Agent - FRU1 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition
54
FRU2 Agent
Discrete
FRU Information Agent - FRU2 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition
55
FRU3 Agent
Discrete
FRU Information Agent - FRU3 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition
56
EventRcv ComLost
Discrete
Detects communication with the event receiver (ShMC) has been lost
Sensor type = 1Bh Cable/Interconnect
Event Reading type code = 03h Digital Discrete
See IPMI v1.5 table 36.2 and table 36.3 for sensor definition
57
IPMC Reboot
Discrete
IPMC reboot detection
Sensor type = 24h Platform Alert
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See IPMI v1.5 table 36.3, Sensor type code 24h for sensor definition
58
IPMC Storage Err
Discrete
Management sub-system health: non volatile memory error
Sensor type = 28h Management Subsystem Health
Event Reading type code = 6Fh Sensor specific, offset 1 is used
See IPMI v1.5 table 36.3, Sensor type code 28h for sensor definition
ID
Sensor Name
Sensor Class
Description (Sensor Type, Event trigger)