beautypg.com

2 ipmc health indicator sensor aggregation – Kontron AT8242 User Manual

Page 62

background image

46

AT8242

www.kontron.com

4.3.2.2

IPMC Health Indicator Sensor Aggregation

The following table shows the sensors involved in the Health Sensor Aggregation.

Table 4-19:IPMC Health Indicator Sensor Aggregation

59

IPMC SEL State

Discrete

Specifies SEL status (Cleared/Almost Full/Full)
Sensor type = 10h Event Logging Disable
Event Reading type code = 6Fh Sensor specific, offset 2,4,5 are used
See IPMI v1.5 table 36.3, Sensor type code 10h for sensor definition

60

Jumper Status

Discrete

Reflects on-board jumper presence
Sensor type = D3h OEM (Kontron OEM Jumper Status)
Event Reading type code = 6Fh Sensor specific, offsets 0 to 14 are used
See OEM table, Sensor type code D3h for sensor definition

61

IPMI Info-1

Discrete

Internal Management Controller firmware diagnostic
Sensor type = C0h Kontron OEM Firmware Info
Event Reading type code = 70h Kontron OEM Internal Diagnostic
See OEM table, Sensor type code C0h and Event/Reading type code 70h for

sensor definition

62

IPMI Info-2

Discrete

Internal Management Controller firmware diagnostic
Sensor type = C0h Kontron OEM Firmware Info
Event Reading type code = 75h Kontron OEM Internal Diagnostic
See OEM table, Sensor type code C0h and Event/Reading type code 75h for

sensor definition

IPMI Sensor ID

Sensor Name

5

Temp Inlet

6

Temp Outlet

7

Temp IPMC

8

Temp Switch

9

Temp SO-DIMM

10

Brd Input Power

11

RTM Power

12

Vcc +12V SUS

13

Vcc +5V SUS

14

Vcc +3.3V SUS

15

Vcc +2.5V SUS

16

Vcc +1.5V SUS

17

Vcc +1.2V SUS

18

Vcc +0.75V SUS

19

Vcc +1.2V Early

20

Vcc +5V

21

Vcc +2.5V

22

Vcc +1.1V

23

Vcc +1.05V

ID

Sensor Name

Sensor Class

Description (Sensor Type, Event trigger)