2 ipmc health indicator sensor aggregation – Kontron AT8242 User Manual
Page 62
46
www.kontron.com
4.3.2.2
IPMC Health Indicator Sensor Aggregation
The following table shows the sensors involved in the Health Sensor Aggregation.
Table 4-19:IPMC Health Indicator Sensor Aggregation
59
IPMC SEL State
Discrete
Specifies SEL status (Cleared/Almost Full/Full)
Sensor type = 10h Event Logging Disable
Event Reading type code = 6Fh Sensor specific, offset 2,4,5 are used
See IPMI v1.5 table 36.3, Sensor type code 10h for sensor definition
60
Jumper Status
Discrete
Reflects on-board jumper presence
Sensor type = D3h OEM (Kontron OEM Jumper Status)
Event Reading type code = 6Fh Sensor specific, offsets 0 to 14 are used
See OEM table, Sensor type code D3h for sensor definition
61
IPMI Info-1
Discrete
Internal Management Controller firmware diagnostic
Sensor type = C0h Kontron OEM Firmware Info
Event Reading type code = 70h Kontron OEM Internal Diagnostic
See OEM table, Sensor type code C0h and Event/Reading type code 70h for
sensor definition
62
IPMI Info-2
Discrete
Internal Management Controller firmware diagnostic
Sensor type = C0h Kontron OEM Firmware Info
Event Reading type code = 75h Kontron OEM Internal Diagnostic
See OEM table, Sensor type code C0h and Event/Reading type code 75h for
sensor definition
IPMI Sensor ID
Sensor Name
5
Temp Inlet
6
Temp Outlet
7
Temp IPMC
8
Temp Switch
9
Temp SO-DIMM
10
Brd Input Power
11
RTM Power
12
Vcc +12V SUS
13
Vcc +5V SUS
14
Vcc +3.3V SUS
15
Vcc +2.5V SUS
16
Vcc +1.5V SUS
17
Vcc +1.2V SUS
18
Vcc +0.75V SUS
19
Vcc +1.2V Early
20
Vcc +5V
21
Vcc +2.5V
22
Vcc +1.1V
23
Vcc +1.05V
ID
Sensor Name
Sensor Class
Description (Sensor Type, Event trigger)