beautypg.com

7 writing output data, Writing output data - 13, Cp383 configuration – Kontron CP383 User Manual

Page 59

background image

CP383

Configuration

ID 27784, Rev. 01

© 2004 Kontron Modular Computers GmbH

Page 4 - 13

27784

.01.VC.040308/162544

P R E L I M I N A R Y

4.4.7

Writing Output Data

Table 4-12: Output Data Register

BITS

TYPE

DEFAULT

FUNCTION

31-8

r/w

0

Reserved

7-0

r/w

0

Data, 8-bit digit

Note ...
Output data is 8 bit (each cluster); this register is read/write enable.

Table 4-13: Output Control Register

BITS

TYPE

DEFAULT

FUNCTION

31-2

r/w

0

Reserved

1

r/w

0

irqen

0

r/w

1

Reset

Note ...
irqen is for diagnostic issuing an interrupt.
The reset bit should be set to 0 to activate a cluster.

Table 4-14: Output Status Register

BITS

TYPE

DEFAULT

FUNCTION

31

r

0

Fail

30

r

0

Diag

29-0

r

0

Reserved

Note ...
The Diag status flag is the diagnostic bit from the HSD switch; Fail is the latched
diag status flag.