KPA3 Connector Replacement

Page 13 of 16

1. Reconnect the coax TMP cables from the KXV3 module to the K144XV module. The cable with the

white marking plugs into 10M IF IN connector and the other cable plugs into the 10M IF OUT connector.

2. Reconnect the power cable as shown in Figure 22. The three-pin power connector is wired so it can be

installed oriented either way. If the KXV3 sub-receiver is installed, route the wire as shown so it is not
trapped under the loudspeaker pad when the top cover is replaced. Be sure the one-pin connector is still
plugged into the K3 RF board.

Figure 22. Attaching the K144XV Power Cable.

3. If the K144XV module includes the Reference Oscillator Phase Lock Option, reconnect the two coax

TMP cables at the REF IN and REF OUT connectors on the K144XV module (see Figure 23). Be sure the
cables have not been accidentally disconnected at the other end.