beautypg.com

Preparing for installation – Elecraft KPA3 Manual User Manual

Page 5

background image

5

We strongly recommend you take the following anti-static precautions (listed in order of importance) to avoid
trouble:

 Leave ESD-sensitive parts in their anti-static packaging until you install them. The packaging may be a

special plastic bag or the component’s leads may be inserted in conductive foam. Parts which are
especially ESD-sensitive are identified in the parts list and in the assembly procedures.

 Wear a conductive wrist strap with a series 1-megohm resistor. If you do not have a wrist strap, touch a

ground briefly before touching any sensitive parts to discharge your body. Do this frequently while you
are working. You can collect a destructive static charge on your body just sitting at the work bench. DO
NOT attach a ground directly to yourself as this poses a serious shock hazard.

 Use a grounded anti-static mat on your work bench.
 If you choose to use a soldering iron to work on your K3 for any reason, be sure your iron has an ESD-

safe grounded tip tied to the same common ground used by your mat or wrist strap.

Preparing for Installation

Tools Required

1. #0 and #1 size Phillips screwdrivers. To avoid damaging screws and nuts, a power screwdriver is not

recommended. Use the screwdriver that best fits the screw in each step.

2. Small diagonal cutters.

3. Needle-nose pliers.

4. Soft cloth or clean, soft static dissipating pad to lay cabinet panels on to avoid scratching.

The following tools are strongly recommended:

1. ESD wrist strap.

2. Static dissipating work pad.