beautypg.com

EFCO S5600 Inside Glazed User Manual

Page 8

background image

EFCO CORPORATION 6/2012 PART NO. Y304

Page 8 of 29

Series 5600 Inside Glazed Installation Instructions

Section IV: Perimeter Application

Determine Installation Method

A.)

Two types of perimeter applications are possible, including “F” perimeter anchors

or mullion anchors with continuous pressure plate pocket fillers. “F” perimeter
anchors should only be used in small “punched” openings that can be assembled

on the floor and set into the opening. Mullion anchors are generally used in

situations where mullions are erected one at a time, in sequence with
corresponding horizontals. Regardless of the installation method selected, the

remaining installation instructions are consistent between the two systems.

Perimeter with Continuous “F” Extrusion

Perimeter with Continuous Pressure Plate Pocket Filler

Fill gasket raceway in top and bottom of

each vertical mullion with sealant to

marry with perimeter sealant

*Note: Perimeter caulking of the primary

seal must be done prior to glazing

when using this application.

See approved shop

drawings for dimension

Cosmetic seal if desired

Pressure plate with return

Continuous “F” clip perimeter

(1/4” shim as required)

Critical Seal Line

Dense preset gasket

Primary seal required

Critical Seal Line

Bed inside corner with sealant

prior to mullion installation

Continuous bead of

sealant in three places

Sealant