beautypg.com

Salter Brecknell WB-521 Series User Manual

Page 53

background image

SBI521 Service Manual

51

NOTE: If AD.FROM = COM2, COM2 and OUT2 will be disabled.

OTHER

NLD.RNG

1-255

10

1-255=the range of weight is 1-
255d. When current weight is
less than this value, the scale
can be regarded as empty, or the
load on scale is removed.
It must be bigger than
(CONFI.MOTION).

CMD.SRC

NONE

COM.1

Source of the executed
command selection

(1)NONE=no any command will
be executed

COM.1

(2)COM.1= command from
COM1 will be executed

COM.2

(3)COM.2= command from
COM2 will be executed

COM1-2

(4)COM.1.2= command from
COM1 or COM2 will be executed

A.OFF.T

0-255

0

Auto off time

0=not auto power off
1-255=auto power off after 1-255
minutes. In this period, no
operation or no weight change

A.OFF.MD

OFF

OFF

Auto off mode

(1)OFF=turn off indicator

DSP.TIM

(2)DSP.TIM= display time

DSP.DAT

(3)DSP.DAT=display date

AC.TIME

(4)AC.TIME=turn off when only
battery is used. Display time
when AC adaptor is used

AC.DATE

(5)AC.DATE=turn off when only
battery is used. Display date
when AC adaptor is used

LCD.BLT

0-255

30

LCD backlight set

(1)0=always off
(1)1=always on
(2)2=press down ZERO+UNIT
together more than 3s to turn on
or turn off
(3)3-255=auto on when key
operation or weight changing.
Auto off after 3-255s elapsed.
*Only available on LCD version

LED.BRT BRT1-2-

3-4-5

BRT3

LED brightness level set

BRT1-BRT2-BRT3=low - high
*Only available on LED version

SCAL.ID 000000-

999999

123456

Scale ID number: 000000-
999999

USER

SubMenu1

SubMenu2

Option

Default

Parameter Description

Comment

This manual is related to the following products: