Salter Brecknell WB-521 Series User Manual
Page 45

SBI521 Service Manual
43
*The setting will be limited by the choice of REGULA
FILTER
FLT1.TH 0-255
40
Digital filter1 threshold:
0=no filter1
1-254=filter1 used only when
vibration in ±0.5d*(1-254)
255= filter1 be always used
FLT1.ST
1-64
8
Digital filter1 intensity
1-64 ADC’s data will be averaged
FLT2.TH
0-255
8
Digital filter2 threshold
0=no filter2
1-254=filter2 used only when
vibration in ±0.25d*(1-254)
255= filter2 be always used
FLT2.ST
0-255
240
Digital filter2 intensity
0-255=weak to strong
FUNC
HOLD
YES
YES
Enable or disable hold
function
YES
NO
NO
COUNT
YES
NO
Enable or disable
counting function
YES
NO
NO
PERCNT
NO
NO
Enable or disable percent
weighing function
(1)NO=disable
(2)100%=enable and display format
is 100%
(3)100.0%=enable and display
format is 100.0%
(4)100.00%=enable and display
format is 100.00%
100%
100.0%
100.00%
COMPAR
YES
YES
Enable or disable data
comparison function
YES
NO
NO
ACCUMU
NO
NO
Accumulation Mode
selection
(1)NO=no accumulation function
(2)MANUAL=add up current number
to accumulation memory after
[TOTAL] key is pressed
(3)AUTO=automatically add up
current number to accumulation
memory after scale is stable and
weight is over (NLD.RNG)
MANUAL
AUTO
WT.ADJ
YES
NO
Enable or disable weight
fine-tuning using keypad
in weighing mode
YES
NO
*If (REGULA) ≠none, this item is
NO
CONFIG
SubMenu1
SubMenu2
Option
Default
Parameter Description
Comment