beautypg.com

Salter Brecknell WB-521 Series User Manual

Page 52

background image

50

SBI521 Service Manual

HOLD

HLD.MOD

NONE

AUTO

Hold mode

(1)NONE=no hold function

PS.PEAK

(2)PS.PEAK=Positive Peak
number Hold mode. Scale will
display and refresh the positive
peak value from last zero setting.

NG.PEAK

(3)NG.PEAK=Negative PEAK
number Hold mode. It is similar to
PS.PEAK, but a negative number
is used.

TOGGLE

(4)TOGGLE=Press [HOLD] key
to enter HOLD mode. If the
weight is over (NLD.RNG) and
stable, the data will be frozen
until the [HOLD] key is pressed
again to exit.

AVERAG

(5) AVERAG= Average HOLD
mode. In this mode, if the weight
is over (NLD.RNG), and its
variation is less than
(DYN.RNG), the average data in
(AVG.TIM) will be frozen. Press
the [HOLD] key or (HLD.TIM)
time elapsed to exit this mode

AUTO

(6)AUTO=Auto hold mode. It is
similar to AVERAG mode, but if
the one held load is removed,
and a new load that is over
(NLD.RNG) put on scale, the new
load will be automatically frozen.

AVG.TIM

1-60

3

Average data time for HOLD
mode

1-60 seconds

STB.TIM 3*AVG.TI

M - 255

3*

AVG.TIM

Wait time for the scale to be
stable in HOLD mode

3*(AVG.TIM) - 255S

HLD.TIM 0-65535

0

Data HOLD time

0=data will be frozen until HOLD
key pressed.
1-65535=data frozen time is 1-
65535s, after the time elapses,
scale will exit HOLD mode.

HLD.RNG 0 - 255

5

Vibration range of data that can
be averaged and held in HOLD
mode

0=any data can be averaged
1-255= only the data which
vibration is in 1-255d can be
averaged and held.

USER

SubMenu1

SubMenu2

Option

Default

Parameter Description

Comment

This manual is related to the following products: