SBI521 Service Manual
27
3.5.1 Enter Count Mode
1.
To enter counting mode press the [FUNC] key for more than 3 seconds.
WEIGH will be displayed.
2.
Use the [N/G] or [PRINT] key to select COUNT.
3.
Press [TARE] to confirm the parts counting mode. The pcs annunciator will be
illuminated.
3a.
In counting mode, the function of [ZERO], [TARE], [PRINT], [HOLD], [TARE],
[N/G], [SETUP], [ON/OFF] keys are available.
3.5.2 Obtain Piece Weight
There are two ways to obtain the piece weight:
Input piece weight directly
1.
Press the [UNIT] key.
2.
When
InP.PWt is displayed, press the [TARE] key to enter into the piece
weight mode.
3.
When
UNIT.KG is shown, use the [PRINT] or [N/G] key to select the unit of
piece weight.
4.
Use the [TARE] key to confirm and go to piece weigh entry.
5.
Press the [ZERO] key to exit the piece weight mode and back to counting
mode.
6.
When last stored piece weight is shown, use [PRINT], [N/G], [UNIT] key to
input new piece weight.
7.
Press the [SETUP] key more than 3 seconds to input decimal point.
8.
Press the [TARE] key to confirm the entry and save it.
8a.
If the input piece weight is less than 0.5d, the indicator will display
PWt.Er
and go back to counting mode.
Sample a Known Quantity
1.
Press the [UNIT] key.
2.
When
InP.PWt is shown, use the [PRINT] or [N/G] key to select SPL.PWT.
3.
Press the [TARE] key to weigh samples (which quantity is known) weight,
calculate piece weight.
4.
When
SPL.Lo is shown, remove the sample on scale and press the [TARE]
key to confirm.
5.
When
SPL.Hi is shown, put samples (its quantity is known) onto the scale,
Press the [TARE] key to confirm reading weight.
6.
After
INP.PCS is displayed, 000000 will be shown. Use the [PRINT], [N/G],
[UNIT] key to input the quantity of samples.
7.