beautypg.com

Trouble shooting — electronics, Model 113.248440 & 113.248510, Problem – Craftsman 113.248510 User Manual

Page 41: No display when, Display shows, Display dim, Probable cause, Suggested corrective action, Trouble shooting—electronics -42

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

trouble shooting — electronics

MODEL 113.248440 & 113.248510

PROBLEM

No display when

is pressed.

Display shows

Display dim.

Display dark.

Display blanks after
a few minutes.

Display shows

C L L L

C C C

L

Display wilt reset to

zero but immediately
shows when bevel is
moved.

C C C C|

C C C L

Display does not

change when bevel

is moved.

PROBABLE CAUSE

1. Battery incorrectly

installed or missing.

2. Battery contacts dirty

or corroded.

3. Battery dead.

4. Digital display failure.

1. Normal display when

battery is first installed in
unit,

2. Bevel display was not

ref-set.

3. Poor battery contact to

indicator display leads

causing intermittent

power to display,

4. Digital display failure.

1. Low battery voltage.

2. Temperature below 32° F.

SUGGESTED CORRECTIVE ACTION

- Adjust battery position in compartment,
- Install battery.

- Clean battery contacts.

- Replace battery Battery is 6 volt, size J,

alkaline type.

- Have electronics checked by qualified

technician. Repair service available at nearest
Sears Store.

- No action required.

Follow procedure for setting bevel reference
point in this manual.

Clean battery contacts. Adjust battery position
in compartment.

Have electronics checked by qualified service
technician. Repair service available at nearest
Sears store.

1. Temperature above 120°F,

1. Normal.

1. Head tilted too rapidly

for digital display to

monitor.

1. Encoder or digital

display defective.

1, Wrong display function

selected.

2. Encoder or digital

display defective.

3. Rib on lower slide

not engaging encoder.

Replace battery. Battery is 6 volt, size J,
alkaline type.

Allow saw to warm above 32° F.

Allow saw to cool below 120° F.

- Press oNiOFF

j

key. Display should return.

- Reset bevel zero reference.

Have electronics checked by qualified

technician. Repair service available at nearest

Sears store.

Select bevel function.

Have electronics checked by qualified

technician. Repair service available

at

nearest

Sears store.

Have

electronics

checked by qualified

technician. Repair service available

at

nearest

Sears

store.

41