It is important to periodically perform a visual check of
the pilot and burner flames. Compare to the illustrations
below. (Figs. 43 & 44) If the flame patterns appear
abnormal contact a qualified service provider for
service and adjustment.
Flame Characteristics
Your log set contains two types of “Lava Rocks”.
The placement of this material is best done after the
logs have been installed.
Ceramic Ember Rocks (Pt. # 57897)
Remove these ‘rocks’ from the packaging and spread
them over the burner tiles in a random fashion to fill up
the spaces between the logs. (Fig. 40) Only place
ceramic embers in areas shown in Figure 40.
Lava Rock (Pt.# 10001454)
Remove this material from the packaging and spread it
over the ceramic floor panels outside the log stack. DO
NOT PLACE THIS MATERIAL ON THE BURNER
TILES.
Lava Rock & Ember Material
Flame & Temperature Adjustment
LG299
Ceramic Ember Rock
Location
Fig. 40 Location of log cradle prongs in relation to assembled
logs.
RN/RP Models
For units equipped with ‘HI/LO’ valves the flame
adjustment is accomplished by rotating the ‘HI/LO’
adjustments knob located near the center of the gas
control valve. (Figs. 41 & 42)
LO
HI
Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
Fig. 41 Flame adjustment knob for Honeywell valve.
LO
HI
Turn
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
Fig. 42 Flame adjustment knob for SIT valve.
3/8" - 1/2"
SIT Pilot
PSE Pilot
FP1394
Fig. 43 Correct pilot flame appearance.
LG300