Vermont Castings, Majestic Products DVRTSB

10003848

General Venting Information – Termination Location

Your fireplace is approved to be vented either through
the rear wall or the vertical side wall, or vertical through
the roof.

Only venting components specifically approved and
labeled for this fireplace may be used.

Venting terminals shall not be recessed into a wall
or siding.

Horizontal venting must be installed on a level plane
without any incline or decline.

There must not be any obstruction such as bushes,
garden sheds, fences, decks or utility buildings within
24" from the front of the termination hood.

Location of Vent Termination

It is imperative the vent termination be located observ-
ing the minimum clearances as shown on this page.

*Check with local codes or in absence of same with
CSAB149.1 Installation Codes (1991) for Canada or
follow the current National Fuel Gas Code,
ANSIZ223.1 for installations in the USA.