beautypg.com

Installing a hot-swap hard drive – Dell POWEREDGE R710 User Manual

Page 83

background image

Installing System Components

83

If the drive has been online, the green activity/fault indicator will flash as
the drive is powered down. When the drive indicators are off, the drive is
ready for removal.

3 Press the button on the front of the drive carrier and open the drive

carrier release handle to release the drive. See Figure 3-5.

4 Slide the hard drive out until it is free of the drive bay.

CAUTION:

To maintain proper system cooling, all empty hard-drive bays must

have drive blanks installed.

5 Insert a drive blank in the vacated drive bay. See "Installing a Hard-Drive

Blank."

6 If applicable, install the bezel. See "Installing the Front Bezel."

Installing a Hot-Swap Hard Drive

CAUTION:

When installing a hard drive, ensure that the adjacent drives are fully

installed. Inserting a hard-drive carrier and attempting to lock its handle next to a
partially installed carrier can damage the partially installed carrier's shield spring
and make it unusable.

CAUTION:

To prevent data loss, ensure that your operating system supports hot-

swap drive installation. See the documentation supplied with your operating
system.

1 If present, remove the front bezel. See "Removing the Front Bezel."
2 If a drive blank is present in the bay, remove it. See "Removing a Hard-

Drive Blank."