beautypg.com

Dell POWEREDGE R710 User Manual

Page 26

background image

26

About Your System

E1313

Fan

redundancy

lost. Check

fans.

The system is no longer fan
redundant. Another fan
failure would put the
system at risk of over-
heating.

Check LCD for additional
scrolling messages. See
"Troubleshooting a Fan."

E1410

System Fatal

Error

detected.

A fatal system error has
been detected.

Check LCD for additional
scrolling messages.
Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help."

E1414

CPU # temp

exceeding

range. Check

CPU heatsink.

Specified processor is out of
acceptable temperature
range.

Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processor(s)" an
d
"Troubleshooting System
Cooling Problems."

E1418

CPU # not

detected.

Check CPU is

seated

properly.

Specified processor is
missing or bad, and the
system is in an unsupported
configuration.

Ensure that the specified
processor is properly
installed. See
"Troubleshooting the
Processor(s)."

E141C

Unsupported

CPU configur-

ation. Check

CPU or BIOS

revision.

Processors are in an
unsupported configuration.

Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.

E141F

CPU #

protocol

error. Power

cycle AC.

The system BIOS has
reported a processor
protocol error.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help."

Table 1-1.

LCD Status Messages (continued)

Code

Text

Cause

Corrective Actions