Dell POWEREDGE R710 User Manual
Page 26
26
About Your System
E1313
Fan
redundancy
lost. Check
fans.
The system is no longer fan
redundant. Another fan
failure would put the
system at risk of over-
heating.
Check LCD for additional
scrolling messages. See
"Troubleshooting a Fan."
E1410
System Fatal
Error
detected.
A fatal system error has
been detected.
Check LCD for additional
scrolling messages.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E1414
CPU # temp
exceeding
range. Check
CPU heatsink.
Specified processor is out of
acceptable temperature
range.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processor(s)" and
"Troubleshooting System
Cooling Problems."
E1418
CPU # not
detected.
Check CPU is
seated
properly.
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
Ensure that the specified
processor is properly
installed. See
"Troubleshooting the
Processor(s)."
E141C
Unsupported
CPU configur-
ation. Check
CPU or BIOS
revision.
Processors are in an
unsupported configuration.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.
E141F
CPU #
protocol
error. Power
cycle AC.
The system BIOS has
reported a processor
protocol error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
Table 1-1.
LCD Status Messages (continued)
Code
Text
Cause
Corrective Actions