beautypg.com

Dell POWEREDGE R710 User Manual

Page 30

background image

30

About Your System

E1715

Fatal I/O

Error. Review

& clear SEL.

The system BIOS has
determined there has been
a fatal error in the system.

Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.

If the problem persists,
see "Getting Help."

E1716

Chipset IERR

Bus

## Dev ##

Function

##.

Review &

clear SEL.

The system BIOS has
reported a chipset internal
error that resides in bus
##, device ##, function
##.

Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.

If the problem persists,
see "Getting Help."

E1717

CPU

#

internal

error. Review

& clear SEL.

The system BIOS has
determined that the
specified processor has had
an internal error.

Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.

If the problem persists,
see "Getting Help."

Table 1-1.

LCD Status Messages (continued)

Code

Text

Cause

Corrective Actions