beautypg.com

Dell PowerEdge 2970 User Manual

Page 31

background image

About Your System

31

Manufacturing mode

detected

System is in manufacturing mode.

Reboot to take the system out of
manufacturing mode.

Memory address line

failure at

address

, read

value

expecting

value

Memory double word logic

failure at

address

, read

value

expecting

value

Memory odd/even logic

failure at

address,

read

value

expecting

value

Memory write/read failure

at

address

, read

value

expecting

value

Faulty or improperly installed memory
modules.

See "Troubleshooting System Memory"
on page 124.

Memory tests terminated by

keystroke.

POST memory test terminated by
pressing the spacebar.

Information only.

No boot device available

Faulty or missing optical/diskette
drive subsystem, hard drive, or hard-
drive subsystem, or no boot disk in
drive A.

Use a bootable diskette, CD, or hard
drive. If the problem persists, see
"Troubleshooting a Diskette Drive" on
page 126, "T
roubleshooting an Optical
Drive" on page 127, and
"Troubleshooting a Hard Drive" on
page
129. See "Using the System Setup
Program" on page 37 for information on
setting the order of boot devices.

No boot sector on hard

drive

Incorrect configuration settings in
System Setup program, or no
operating system on hard drive.

Check the hard-drive configuration
settings in the System Setup program.
See "Using the System Setup Program"
on page 37. If necessary
, install the
operating system on your hard drive. See
your operating system documentation.

No timer tick interrupt

Faulty system board.

See “"Getting Help" on page 147."

Not a boot diskette

No operating system on diskette.

Use a bootable diskette.

PCI BIOS failed to install

PCIe device BIOS (Option ROM)
checksum failure detected during
shadowing.

Cables to expansion card(s) loose;
faulty or improperly installed
expansion card(s).

Reseat the expansion card(s). Ensure
that all appropriate cables are securely
connected to the expansion card(s). If
the problem persists, see
"Troubleshooting Expansion Cards" on
page 132.

Table 1-7.

System Messages (continued)

Message

Causes

Corrective Actions