22

About Your System

E1311

RPM Fan Mod ##

RPM of specified cooling fan is
out of acceptable operating range.

See "Troubleshooting System
Cooling Problems" on page 123.

E1313

Fan Redundancy

The system is no longer fan-
redundant. Another fan failure
will put the system at risk of over-
heating.

Check control panel LCD for
additional scrolling messages. See
"Troubleshooting System Cooling
Problems" on page 123.

E1410

CPU # IERR

Processor # has had an internal
error (IERR) that is possibly, but
not always, caused by a problem
with the CPU.

See "Getting Help" on page 147.

E1414

CPU # Thermtrip

Specified microprocessor is out of
acceptable temperature range and
has halted operation.

See "Troubleshooting System
Cooling Problems" on page 123.
If the problem persists, ensure
that the microprocessor heat
sinks are properly installed. See
"Troubleshooting the
Microprocessors" on page 133.

NOTE:

The LCD continues to

display this message until the
system’s power cord is
disconnected and reconnected to
the AC power source, or the SEL is
cleared using either Server
Assistant or the BMC Management
Utility. See the Dell OpenManage
Baseboard Management
Controller User’s Guide

for

information about these utilities.

E1418

CPU # Presence

Specified processor is missing or
bad, and the system is in an
unsupported configuration.

See "Troubleshooting the
Microprocessors" on page 133.

E141C

CPU Mismatch

Processors are in a configuration
unsupported by Dell.

Ensure that your processors
match and conform to the type
described in the Microprocessor
Technical Specifications outlined
in your system’s Getting Started
Guide.

E141F

CPU Protocol

The system BIOS has reported a
processor protocol error.

See "Getting Help" on page 147.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions