About Your System
E2017
Timer Fail
Timer refresh failure.
See "Getting Help" on page 147.
E2018
Prog Timer
Programmable interval timer
error.
See "Getting Help" on page 147.
E2019
Parity Error
Parity error.
See "Getting Help" on page 147.
E201A
SIO Err
SIO failure.
See "Getting Help" on page 147.
E201B
Kybd Controller
Keyboard controller failure.
See "Getting Help" on page 147.
E201C
SMI Init
System management interrupt
(SMI) initialization failure.
See "Getting Help" on page 147.
E201D
Shutdown Test
BIOS shutdown test failure.
See "Getting Help" on page 147.
E201E
POST Mem Test
BIOS POST memory test failure. See "Troubleshooting System
Memory" on page 124. If problem
persists, see "Getting Help" on
page 147.
E201F
DRAC Config
Dell remote access controller
(DRAC) configuration failure.
Check screen for specific error
messages.
Ensure that DRAC cables and
connectors are properly seated. If
problem persists, see your DRAC
documentation.
E2020
CPU Config
CPU configuration failure.
Check screen for specific error
messages.
E2021
Memory
Population
Incorrect memory configuration.
Memory population order
incorrect.
Check screen for specific error
messages. See "Troubleshooting
System Memory" on page 124.
E2022
POST Fail
General failure after video.
Check screen for specific error
messages.
E2110
MBE DIMM # & #
One of the DIMMs in the set
implicated by "# & #" has had a
memory multi-bit error (MBE).
See "Troubleshooting System
Memory" on page 124.
E2111
SBE Log Disable
DIMM #
The system BIOS has disabled
memory single-bit error (SBE)
logging, and will not resume
logging further SBEs until the
system is rebooted. "#" represents
the DIMM implicated by the
BIOS.
See "Troubleshooting System
Memory" on page 124.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions