beautypg.com

Dell PowerEdge 2970 User Manual

Page 25

background image

About Your System

25

E1810

HDD ## Fault

The SAS subsystem has
determined that hard drive ##
has experienced a fault.

See "Troubleshooting a Hard
Drive" on page 129.

E1811

HDD ## Rbld Abrt

The specified hard drive has
experienced a rebuild abort.

See "Troubleshooting a Hard
Drive" on page 129. If the
problem persists, see your RAID
documentation.

E1812

HDD ## Removed

The specified hard drive has been
removed from the system.

Information only.

E1914

DRAC5 Conn2 Cbl

DRAC 5 cable is missing or
disconnected.

Reconnect the cable. See
"Installing a RAC Card" on
page 81.

E1A12

PCI Rsr Missing

One or all of the PCIe risers is
missing, preventing the system
from powering on.

Reinstall the missing riser card(s).

E1A14

SAS Cable A

SAS cable A is missing or bad.

Reseat the cable. If the problem
persists, replace cable. See "SAS
Controller Daughter Card" on
page 65.

E1A15

SAS Cable B

SAS cable B is missing or bad.

Reseat the cable. If the problem
persists, replace cable. See "SAS
Controller Daughter Card" on
page 65.

E2010

No Memory

No memory is installed in the
system.

Install memory. See "Installing
Memory Modules" on page 94.

E2011

Mem Config Err

Memory detected, but is not
configurable. Error detected
during memory configuration.

See "Troubleshooting System
Memory" on page 124.

E2012

Unusable Memory

Memory is configured, but not
usable. Memory subsystem
failure.

See "Troubleshooting System
Memory" on page 124.

E2013

Shadow BIOS Fail

The system BIOS failed to copy
its flash image into memory.

See "Troubleshooting System
Memory" on page 124.

E2014

CMOS Fail

CMOS failure. CMOS RAM not
functioning properly.

See "Getting Help" on page 147.

E2015

DMA Controller

DMA controller failure.

See "Getting Help" on page 147.

E2016

Int Controller

Interrupt controller failure.

See "Getting Help" on page 147.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes