25
E1810
HDD ## Fault
The SAS subsystem has
determined that hard drive ##
has experienced a fault.
See "Troubleshooting a Hard
Drive" on page 129.
E1811
HDD ## Rbld Abrt
The specified hard drive has
experienced a rebuild abort.
See "Troubleshooting a Hard
Drive" on page 129. If the
problem persists, see your RAID
documentation.
E1812
HDD ## Removed
The specified hard drive has been
removed from the system.
Information only.
E1914
DRAC5 Conn2 Cbl
DRAC 5 cable is missing or
disconnected.
Reconnect the cable. See
"Installing a RAC Card" on
page 81.
E1A12
PCI Rsr Missing
One or all of the PCIe risers is
missing, preventing the system
from powering on.
Reinstall the missing riser card(s).
E1A14
SAS Cable A
SAS cable A is missing or bad.
Reseat the cable. If the problem
persists, replace cable. See "SAS
Controller Daughter Card" on
page 65.
E1A15
SAS Cable B
SAS cable B is missing or bad.
Reseat the cable. If the problem
persists, replace cable. See "SAS
Controller Daughter Card" on
page 65.
E2010
No Memory
No memory is installed in the
system.
Install memory. See "Installing
Memory Modules" on page 94.
E2011
Mem Config Err
Memory detected, but is not
configurable. Error detected
during memory configuration.
See "Troubleshooting System
Memory" on page 124.
E2012
Unusable Memory
Memory is configured, but not
usable. Memory subsystem
failure.
See "Troubleshooting System
Memory" on page 124.
E2013
Shadow BIOS Fail
The system BIOS failed to copy
its flash image into memory.
See "Troubleshooting System
Memory" on page 124.
E2014
CMOS Fail
CMOS failure. CMOS RAM not
functioning properly.
See "Getting Help" on page 147.
E2015
DMA Controller
DMA controller failure.
See "Getting Help" on page 147.
E2016
Int Controller
Interrupt controller failure.
See "Getting Help" on page 147.
Table 1-6.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions