beautypg.com

Dell PowerEdge 2970 User Manual

Page 16

background image

16

About Your System

Table 1-3 lists the drive indicator patterns for RAID hard drives. Different patterns are displayed as drive
events occur in the system. For example, if a hard drive fails, the "drive failed" pattern appears. After the
drive is selected for removal, the "drive being prepared for removal" pattern appears, followed by the "drive
ready for insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared for
operation" pattern appears, followed by the "drive online" pattern.

NOTE:

For non-RAID configurations, only the drive-activity indicator is active. The drive-status indicator is off.

Table 1-3.

Hard-Drive Indicator Patterns for RAID

Condition

Drive-Status Indicator Pattern

Identify drive/preparing for
removal

Blinks green two times per second

Drive ready for insertion or
removal

Off

Drive predicted failure

Blinks green, amber, and off.

Drive failed

Blinks amber four times per second.

Drive rebuilding

Blinks green slowly.

Drive online

Steady green.

Rebuild aborted

Blinks green three seconds, amber three seconds, and off six seconds.